check / check (push) Successful in 55s
Report files were named by a millisecond timestamp and created with O_EXCL, so two flushes in the same millisecond, such as a flush for size and the final flush at shutdown, got the same name and the second failed, losing its reports. Each name now carries a number after the timestamp that goes up by one for each file the server starts to write, so names still sort by time and never repeat within a run; a failed write leaves a gap in the numbers. The buffer reads the time through a clock the new test stops, so its two flushes share one timestamp on every run; the 1 ms pauses earlier tests used to dodge the collision are gone. Model: opus-5-5
16 lines
439 B
Go
16 lines
439 B
Go
package reportbuf
|
|
|
|
import "time"
|
|
|
|
// Flush writes the buffered reports to a file now, as the periodic
|
|
// flush does, so tests need not wait a minute for it.
|
|
func (b *Buffer) Flush() error {
|
|
return b.flushLocked()
|
|
}
|
|
|
|
// StopClock makes every report file the buffer writes from now on
|
|
// carry the timestamp at, as if all were written in one millisecond.
|
|
func (b *Buffer) StopClock(at time.Time) {
|
|
b.now = func() time.Time { return at }
|
|
}
|