Target.MaxRetries (max_retries) becomes Target.MaxAttempts
(max_attempts), and the form field, parser and ceiling are renamed to
match. 1 is a single attempt with no circuit breaker; above 1 retries
behind the breaker up to that many attempts. Both target forms refuse
0 and less and default a blank field to 1. The target page shows the
plain number, and the README's two paragraphs on 0 against 1 become
one sentence.
Model: opus-5-5
The target toggle loaded the target, flipped its active flag and saved the whole row, so an edit of the same target's name or settings saved in between was written back over and lost, although it reported success. The toggle now updates only the active column, so it can no longer undo an edit. A test saves an edit just after the toggle has read the target and shows the edit survives and the state flips. The entrypoint toggle is unchanged, since an entrypoint has no edit form.
Model: opus-5-5