Target.MaxRetries (max_retries) becomes Target.MaxAttempts
(max_attempts), and the form field, parser and ceiling are renamed to
match. 1 is a single attempt with no circuit breaker; above 1 retries
behind the breaker up to that many attempts. Both target forms refuse
0 and less and default a blank field to 1. The target page shows the
plain number, and the README's two paragraphs on 0 against 1 become
one sentence.
Model: opus-5-5
Seven error checks in internal/delivery/target_http.go could be removed without any test noticing, among them withRetry's check on writing the delivery result, the branch that leaves a sent delivery retrying and recoverable when its bookkeeping write fails. Each now fails a test when removed. The "send succeeded" case starts from a tripped circuit breaker, so a probe whose send succeeds but whose result write fails must still close the breaker. The checks in remainingBackoff and backoffElapsed stay unpinned: removing them gives the same answer, and they state a rule a reader needs. Test change only.
Model: opus-5-5