When the non-VPN physical gateway is a Starlink dish, two lines are shown under that pane: state, uptime, obstruction and alert count; then pop-ping latency and drop rate with downlink/uplink throughput. They turn red when the dish is not connected or an alert is active. Detection is a TCP connect to the dish's fixed endpoint 192.168.100.1:9200, bound to the physical interface the same way the latency probes bind. Until a dish answers nothing is drawn and no status is fetched, so an absent dish adds no noise. Status comes from the dish's local get_status gRPC call. Detection and the fetch sit behind a small Client interface; the loop and the pure Render function are tested with a fake, no dish and no network. Model: opus-4-8