Tests that wait on the real clock failed when the host stalled for a few seconds, although the code was right. Waits for something that should happen are now mostly 15 seconds. Tests whose result depends on a short idle timeout or a production request limit run under `synctest.Test`, on a fake clock, with a fake transport where a real connection would stop that clock. Test code only. Judgement call: the 5-second waits in three `internal/streamer` tests also became 15 seconds. Model: opus-5-5
This commit was merged in pull request #242.
This commit is contained in:
1 parent
28ef0275ba
commit
641798bb22
10 files changed
+337
-187
No files matched your search
@@ -72,17 +72,34 @@ const (
|
||||
// lockTestPrefix is the prefix the batch writes in the checkpoint tests
|
||||
// store.
|
||||
lockTestPrefix = "192.0.2.0/24"
|
||||
// longBusyTimeoutMs is the busy timeout setLongBusyTimeout gives the
|
||||
// writing connection. A checkpoint that waits for an open read takes this
|
||||
// long.
|
||||
longBusyTimeoutMs = 30000
|
||||
// readerCheckpointLimit is how long a checkpoint, and a batch write
|
||||
// waiting for it, may take while a reader is open: well under the busy
|
||||
// timeout, which a checkpoint that waits for the reader takes.
|
||||
readerCheckpointLimit = time.Second
|
||||
// waiting for it, may take while a reader is open: well under
|
||||
// longBusyTimeoutMs, with room for a stall on a busy host.
|
||||
readerCheckpointLimit = 15 * time.Second
|
||||
// truncateCheckpointLimit is how long a checkpoint of a WAL file over
|
||||
// sqliteWALSizeLimitBytes may take to give up while a reader is open: its
|
||||
// wait for the reader plus a second, well under the busy timeout.
|
||||
// wait for the reader plus readerCheckpointLimit.
|
||||
truncateCheckpointLimit = truncateBusyTimeoutMs*time.Millisecond +
|
||||
time.Second
|
||||
readerCheckpointLimit
|
||||
)
|
||||
|
||||
// setLongBusyTimeout gives the writing connection of db longBusyTimeoutMs, so
|
||||
// that a checkpoint that waits for an open read takes far longer than a stall
|
||||
// on a busy host.
|
||||
func setLongBusyTimeout(ctx context.Context, t *testing.T, db *Database) {
|
||||
t.Helper()
|
||||
|
||||
_, err := db.writer.ExecContext(ctx,
|
||||
fmt.Sprintf("PRAGMA busy_timeout=%d", longBusyTimeoutMs))
|
||||
if err != nil {
|
||||
t.Fatalf("failed to set the busy timeout: %v", err)
|
||||
}
|
||||
}
|
||||
|
||||
// TestConnectionPoolPragmas holds several pooled connections open at once and
|
||||
// checks each one carries the per-connection settings from the DSN, plus the
|
||||
// process-wide heap limits, and sees the new file with auto_vacuum
|
||||
@@ -579,6 +596,8 @@ func TestCheckpointDoesNotWaitForReader(t *testing.T) {
|
||||
ctx := context.Background()
|
||||
ts := time.Now().UTC()
|
||||
|
||||
setLongBusyTimeout(ctx, t, db)
|
||||
|
||||
err = db.UpdatePrefixesBatch(map[string]time.Time{"198.51.100.0/24": ts})
|
||||
if err != nil {
|
||||
t.Fatalf("failed to store the prefix the reader reads: %v", err)
|
||||
@@ -690,6 +709,7 @@ func TestCheckpointEmptiesWALOnceNoReadIsOpen(t *testing.T) {
|
||||
}
|
||||
|
||||
fillWALPastLimit(ctx, t, db)
|
||||
setLongBusyTimeout(ctx, t, db)
|
||||
|
||||
started := time.Now()
|
||||
|
||||
|
||||
Reference in new issue